The RF (Radio Frequency) Admittance Level Sensor have been a part of the industry since 1970s. The major challenge addressed by this family of products is immunity to application media buildup on the probe, thus making level sensing more reliable.
Depending on the density of bulk solids and process temperature Sapcon Instruments offers the following construction for Rod Probe Sub-Types:
Probe Sub-Type Application Media Density Process Temperature Typical Application
Extra Strong - ES Low Bulk Density 250 ℃ Polyester Chips
PVC granules
Light Chemical Powder
Flour
Extra Sturdy - XS Medium Bulk Density 250 ℃ Cement Storage
Sand
Coal
Heavy Duty - HD Low to Medium Bulk Density 300℃ to 1000℃ Furnace
Air Quenching Chamber
Cement Clinker Crusher
Sinter Plant (Iron Ore)
Pellet Plant
Super Strong - SS High Bulk Density 250℃ Clinker Cooling
Electrostatic Precipitator (ESP Hopper)
Bag Filter
All the above probe configurations are availble with the following products :