Elefant Level Transmitter for De­-oiled Toaster

Sapcon’s Elefant Level Transmitter for De­-oiled Toaster is a special solution that was developed primarily for Soya industries. This sensor is ideal for continuous level measurement of the application material.

Elefant works on the principle of physical movement of float. Due to movement of float up and down shaft rotates and the inner variable capacitor changes the value of capacitance. This change in capacitance can be calculated to show the output in terms of current (mA).

Approvals and Certificates for Elefant Level Transmitter for De­-oiled Toaster

  • CIMFR for hazardous Gas Groups IIA and IIB
  • Weatherproof IP-­65 certification for evaluation unit
  • ISI mark for operability in hazardous area
  • ROHS compliance
  • CE compliance

Follow us on LinkedIn

Principle

Sapcon Elefant continuous Monitoring sensor works on the principle of physical movement of float. A single shaft float is inserted in the DT chamber. Shaft which has a counter coupling can be connected to the shaft of the elefant probe. Due to movement of float up and down shaft rotates and the inner variable capacitor changes the value of capacitance. This change in capacitance can be calculated of the evaluation unit to show the mA output.

Features
  • Special solution for de-oil toaster
  • Exclusively for soya industries
  • High accuracy and stability
  • Flameproof enclosure for gas group IIA and IIB
  • Rugged design
Mechanical Specifications

EVALUATION UNIT

  • Weatherproof wall mounting or panel mounting
  • 3 X 1/2″ BSP / NPT cable entries

PROBE AND MOUNTING

  • Flameproof housing suitable for Gas Group IIA, IIB
  • Fixed plate mounting with roatary shaft and coupling
Electrical Specifications

ELECTRONIC UNIT WITH VARIABLE CAPACITOR

Power Supply

  • 90-265 V AC, 50 Hz
  • 24 V DC

Outputs

  • 03 SPDT Relay Output
  • 4-20mA Current Output
  • Display: 0-100% Seven Segment
Application Specifications

For continuous Monitoring in De-Oil Toaster, specially in Soya Extraction plants

Certification
  • CIMFR for hazardous Gas Group IIA and IIB
  • ISI mark for hazardous area
  • Weatherproof IP-67 for evaluation unit
  • CE compliance
  • ROHS compliance
Switching Indication
  • Seven Segment Display
  • 3 LED’s for various relay outputs