Electromechanical
RF-Capacitance
RF-Admittance
Conductivity
Speed
Admittance Level Limit Switch (SLA Series)

The SLA series of admittance based level switches are designed to offer interference free signal transmission from the electronic insert to the evaluation unit. This level control has no moving parts, no mechanical wear and tear and offers added reliability in form of system fault detection. One can , calibrate the system from a remote location and the evaluation unit can be installed away from the the probe. The calibration controls are available in the evaluation unit.

The SLA admittance level sensor has a fail-safe high/low Selection feature available as a standard. This helps in reducing inventory since the same evaluation unit can be field-configured either for high or low level fail-safe detection. The system ignores the built-up of sticky and conductive material between the probe and the vessel walls. The system is based on a 3-electrode technique with coat-immunizing circuitry to create inactive region. The system is economic to install and uses ordinary 3-Core cable for interconnecting the electronic insert with the evaluation unit.

 
Applications
The SLA series of level instruments works well with a range of serive materials such as fine, coarse, solids, liquids and slurries, conductive or non-conductive, corrosive or non-corrosive that have a tendency to stick and coat. The system can be used to switch off conveyors when the vessel is full to avoid overflow. A major application is for indicating an empty tank well in time to avoid production stoppage and for pump control. Our customers have successfully used the SLA series of level indicators and controls in the Cement, Food, Chemicals, Fertilizer, Sugar, Cosmetics, Detergent and many other industries.
Measuring System
The SLA series consists of an evaluation unit, an electronic insert and a probe. The probe is mounted either from top or side of the vessel. The probe comprises sense and shield electrodes electrically isolated from the metallic tank by means of insulators. The sense electrode and the vessel wall serve as the two electrodes of an imperfect capacitor with the service material as the dielectric. A change in material level causes a change in admittance of this tank capacitor. An accurate measurement of this change affords an indirect measure of the level of material in the tank. The electronic insert measures the change of admittance accurately by using Radio Frequency (R.F.) technique coupled to a DC voltage variation, which is transmitted to the evaluation unit via
3-core unscreened cable for further processing. The processed signal is used to energize or de-energize a relay whose output contacts are available for annunciation or control.
 

Technical Data

Electronic Insert - ICA 3000
Housing : Plastic , potted in epoxy resin.
Measuring Frequency ~ 500 KHz.
Ambient Temp. : -20º C to + 80º C.
Supply Voltage : 15 V derived from evaluation unit.
Output Signal : 3 to 12 V DC.
Evaluation Unit
Housing : Cast Aluminum, Weather proof, back panel/wall mounting
Cable Entry : 3 Nos.
Max. Amb. Temp. : - 20º C to + 60º C.
Power Consumption : 5 VA approx.
Mains Voltage : 230 V or 110 V AC (-15% to +10%), 50 Hz; 24V AC/DC on request (to be specified while ordering).
Relay Output : One/two sets of potential free change over contacts rated at 230V AC 6A, 50 Hz for non-inductive loads
  per set point.
Fail Safe Mode : Max. or Min. Field selectable. Indication Red LED for alarm, Green LED for normal, Yellow LED for
  system fault.
Indication : Red LED for alarm, Green LED for normal.
Response Time : 0.2 Second

Switching Delay for SLA 322/622/
822/922

: Adjustable from 0.5 to 20 Second. for probe covered or uncovered.

Connection to Electronic Insert

: 3 - core unscreened cable.
Initial Capacitance
SLA 122/222
322/622/822
SLA 522/722/922

: 0 to 290 pf. in 3 overlapping ranges.

: 0 to 1200 pf. in 3 overlapping ranges.

Switching /Hysteresis
SLA 122/222/
322/622/822
SLA 522/722/922


: 0.5 pf. typical.

: Continuously adjustable over the entire range.

SLA.........Series

ELECTRONICS
MODEL
TEMPERATURE
ENCLOSURE
MOUNTING ARRANGEMENT *
       Size Type (BSP, NPT, ANSI, DIN, JIS, SMS or Any other)
MOUNTING/WETTED PART MATERIAL
Probe Length required -
Quantity
 

  


Home | Company | Level Measurement | Speed Monitoring | Major Market |
Articles | Distributors | Contact Us | News | Application | Sitemap

Fax: +91-731- 2475475 Phone: +91-731-4085751 Email: sales@sapconinstruments.com